Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Rev. Col. Bras. Cir ; 41(5): 357-365, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-729961

ABSTRACT

Objective: The paper analyzes the supply and the utilization of hemodynamic services in Rio de Janeiro, Brazil. Methods: It's an exploratory study that uses data obtained from Brazilian official databases. The period of supply analysis was from 1999 to 2009, and of utilization was from 2008 to October 2012. Results: Since 1999 there is a growth of hemodynamic equipment purchase. The private sector concentrates most of the supply, but it has been reducing its availability to SUS. The rate between population and equipment in Brazil exceeds the ones of some rich countries. In the sense of supply, there are in 2009, a supply rate of 1,4 equipments for 1 million inhabitants in RJ state, larger than brazilian rate, of 3,4 but the rates are similar for public customers. Conclusion: Interventional cardiology procedures have improved in the state, but in a different way. And this is because the public hospitals at Rio de Janeiro have mostly reduced their production, while the private ones have increased their production. The observed result is the SUS users performing their procedures at great distances. .


Objetivo: analisar a oferta dos equipamentos e a utilização dos procedimentos inerentes aos serviços públicos de hemodinâmica no estado do Rio de Janeiro, Brasil. Métodos: Estudo exploratório, a partir de bancos de dados oficiais: pesquisa AMS do IBGE, CNES, AIH e APAC, e da ANS. O período de análise da oferta foi de 1999 a 2009 e o da utilização, de 2008 a outubro de 2012. Resultados: Desde 1999 há crescimento na aquisição dos equipamentos de hemodinâmica. O setor privado concentra grande parte da oferta, mas vem reduzindo sua disponibilidade ao Sistema Único de Saúde (SUS). A taxa de equipamentos pela população supera a de alguns países ricos. Quanto à oferta, havia, no Rio de Janeiro, em 2009, uma taxa de 4,1 aparelhos por milhão de habitantes maior do que no Brasil, de 3,4, mas considerando apenas a oferta para o SUS, os valores são semelhantes, de 1,6 e 1,5. Conclusão: Os procedimentos de cardiologia intervencionista cresceram entre 2008 e 2011 no RJ mas os hospitais públicos na sua maioria têm reduzido a produção e os privados aumentado, resultando no encaminhamento dos usuários do SUS para realizar os procedimentos a grandes distâncias. .


Subject(s)
Humans , Radiography, Interventional/statistics & numerical data , Diagnostic Techniques, Cardiovascular/statistics & numerical data , Health Services/supply & distribution , Health Services/statistics & numerical data , Hemodynamics , Brazil
2.
Rev. argent. cir ; 77(3/4): 84-9, sept.-oct. 1999. ilus, tab
Article in Spanish | LILACS | ID: lil-252930

ABSTRACT

Antecedentes: Los métodos clásicos de diagnóstico no invasivo para la detección de obstrucción biliar han sido la ecografía y la tomografía axial computarizada. La eficacia de estas técnicas se encuentra limitada por la baja sensibilidad en el diagnóstico de la litiasis de la vía biliar principal y la evaluación de estenosis de la misma. Objetivo: Evaluar la experiencia inicial en colangiorresonancia y su comparación con métodos invasivos de comprobada eficacia. Diseño: Estudio prospectivo no randomizado. Población: Fueron evaluadas en los Servicios de Cirugía General y Torácica del Hospital Francés y de Cirugía Gastroenterológica del Hospital de Clínicas, 218 colangiorresonancias. En 44 casos se comparó la CNM con métodos contrastados, evaluando su sensibilidad y especificidad. La población estudiada presentaba sintomatología compatible con obstrucción de la vía biliar o estenosis de anastomosis biliodigestivas. Método: Se delinearon dos grupos de pacientes: Grupo 1: Pacientes con síndrome de hipertensión canicular con patología obstructiva benigna y maligna (32 casos). Grupo 2: Pacientes con síndrome de hipertensión canicular en derivaciones biliodigestivas (12 casos). Resultados: En el grupo 1 la sensibilidad de la CNM fue de 93,7 por ciento, contra un 96,8 por ciento de los estudios contratados; la especificidad fue del 96,8 por ciento y 100 por ciento respectivamente. En el grupo 2 la sensibilidad de la CNM fue del 58,3 por ciento contra un 91,6 por ciento de los estudios contrastados y la especificidad del 91,6 contra un 100 por ciento respectivamente. Conclusiones: Consideramos a la CNM, como una técnica rápida, sencilla y sin riesgo. Las imágenes obtenidas resultan de fácil interpretación al ser similares a las observadas en la CRE y por otra parte, pueden correlacionarse con los elementos circundantes en los cortes axiales. Posee además, la cualidad de poder observar en un sólo estudio y en una misma imagen todo el árbol biliar tanto en la zona supra como infra estenótica


Subject(s)
Humans , Algorithms , Cholangiography , Cholelithiasis/diagnosis , Cholestasis/diagnosis , Magnetic Resonance Spectroscopy , Anastomosis, Surgical/adverse effects , Diagnostic Imaging/statistics & numerical data , Diagnostic Imaging/trends , Radiography, Interventional/statistics & numerical data , Radiography, Interventional/trends , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL